TM 9-2320-363-34-1
NOTE
If the desiccant cartridge inside the receiver-drier has fallen apart, evacuate the
system and replace the expansion valve and the refrigerant compressor (desiccant
matter cant be removed from these parts). A cartridge may fall apart from too much
moisture in the system, because of poor evacuation of the system, or lack of
maintenance.
Do not disconnect or connect refrigerant fittings using only one wrench. Hold one
fitting in place using a wrench, and turn the other fitting with a second wrench.
1.
TAG AND DISCONNECT REFRIGERANT LINES (1) FROM THE RECEIVER-DRIER (2).
INSTALL PLUGS IN THE REFRIGERANT LINES. DISCARD PREFORMED PACKINGS.
2.
LOOSEN HOSE CLAMP (3) ATTACHING
THE RECEIVER-DRIER (2) TO THE
MOUNTING BRACKET AND REMOVE
THE RECEIVER-DRIER.
1.
POSITION THE RECEIVER-DRIER (2) IN THE MOUNTING BRACKET. TIGHTEN THE HOSE
CLAMP (3) SECURELY.
2.
REMOVE THE PLUGS FROM THE REFRIGERANT LINES (1) AND THE LINE PORTS ON THE
NEW RECEIVER-DRIER (2). INSTALL NEW PREFORMED PACKINGS AND APPLY
REFRIGERANT OIL TO THEM. APPLY LOCTITE 242Ò TO THE MALE FITTING THREADS AND
CONNECT THE REFRIGERANT LINES TO THE RECEIVER-DRIER. USING TWO WRENCHES TO
AVOID TWISTING THE TUBING, TIGHTEN THE CONNECTIONS TO THE VALUES IN TABLE D-3,
APPENDIX D.
3.
SERVICE AIR CONDITIONER COMPRESSOR (page 11 .1-23).
NOTE
Follow-on Maintenance:
Install fan cycling switch (page 11 .1-21).
Install binary switch (TM 9-2320-363-20).
Connect batteries (TM 9-2320-363-20).
Charge and leak test air conditioning system (page 11.1-2 and TM 9-2320-363-20).
Check operation of air conditioning system (TM 9-2320-363-10).
Change 1
11.1-15