TM 9-2320-363-34-1
AIR CONDITIONER COMPRESSOR REPLACEMENT (CONT)
1.
DISCONNECT CONNECTOR (1) OF COMPRESSOR (2) FROM CONNECTOR (3).
CAUTION
Water and dirt can damage the refrigerant system. Five minutes of
not being capped is the limit for any hose or component. Do not blow
shop air through the refrigerant hoses; shop air is wet (humid).
NOTE
Do not disconnect or connect refrigerant fittings using only one wrench. Hold one fitting in
place using a wrench, and turn the other fitting with a second wrench.
2.
TAG AND DISCONNECT TWO HOSES (4) FROM TOP OF COMPRESSOR (2). INSTALL PLUGS
IN LINES AND DISCARD PREFORMED PACKING (5).
3.
REMOVE TWO SCREWS (6) WASHERS (7) LOCK NUTS (8) AND COMPRESSOR (2) WITH
BRACKET (9) ATTACHED. DISCARD LOCK NUTS.
4.
5.
SECURE BRACKET (9) IN SOFT JAWED VISE.
REMOVE SCREW (10), WASHER (11) AND SPACER (12) FROM ALTERNATOR ADJUSTMENT
BOLT (13).
6.
REMOVE SCREW (14) AND LOCK WASHER (15) FROM SIDE OF COMPRESSOR BRACKET (9).
DISCARD LOCK WASHER.
7.
REMOVE THREE SCREWS (16) AND LOCK WASHERS (17) FROM SIDE OF COMPRESSOR
BRACKET (9). DISCARD LOCK WASHERS.
8.
REMOVE TWO SCREWS (18) AND LOCK WASHERS (19) FROM UNDERSIDE OF COMPRESSOR
BRACKET (9).
9.
REMOVE COMPRESSOR (2) FROM BRACKET (9).
11.1-10 Change 1