TM 9-2320-363-34-1
1.
SOAK ROCKER ARM SHAFT (1) IN DRYCLEANING SOLVENT. RUN WIRE BRUSH THRU CENTER
OIL PASSAGE (2).
W A R N I N G
To prevent injury, compressed air will not exceed 30 psi (207 kPa). Use only
with effective chip guarding and personal protective equipment, goggles,
shield, and gloves.
2.
BLOW OUT CENTER OIL PASSAGE (2) AND OIL HOLES (3) WITH COMPRESSED AIR.
EXTERIOR WITH CLEAN, LINT-FREE RAGS.
WIPE
1.
INSPECT ROCKER ARM SHAFT (1) WHERE CONTACT IS MADE WITH ROCKER ARM BUSHINGS
(2). IF ROCKER ARM SHAFT (1) DIAMETER IS LESS THAN 1.415 IN. (35.943 mm) MINIMUM,
REPLACE SHAFT.
3-187