TM 9-2320-363-20-1
Table 2-2. Unit Preventive Maintenance Checks and Services (PMCS) for the M915 Family of Vehicles (Cont).
Location
Item
Item to Check/
Not Fully Mission
No.
Interval
Service
Procedure
Capable if:
WARNING
Dry cleaning solvent, P-D-680, is toxic
and flammable. Always wear
protective goggles and gloves, and
use only In a well-ventilate d area.
Avoid contact with skin, eyes, and
clothes, and DO NOT breathe vapors.
DO NOT use near open flame or
excessive heat. The solvent's flash
point is 100°F-138°F (38°C-59°C). If
you become dizzy while using cleaning
solvent, immediately get fresh air and
medical help. If solvent contacts eyes,
immediately wash your eyes and seek
medical attention.
31
Semi-
Transfer Case ,
b.
Remove breather (35) from transfer
(Cont)
annual
(All Except
case. Clean with dry cleaning solvent
M915A2)
(Item 25, Appendix C) and allow to
air dry. Install breather in transfer
case (page 4-384).
c.
Inspect transfer case for loose or
damaged bolts. Tighten any loose
bolts. Check for signs of leakage
from oil seals. Notify Direct Support
Maintenance if damage or leaks are
found.
2-18.18 Change 3