TM 9-2320-363-20-1
Section 4
TROUBLESHOOTING CHARTS
FLASH CODE:
62
DDR DISPLAY:
(AUXILIARY OUTPUT #6) SHORT TO BATTERY (+)
SAE J1587 CODE:
SID: 054 FMI: 3
Indicates that the function assigned to the Auxiliary Output #6 circuit output is shorted to battery (+). This diagnostic
condition is detected when the DDEC III ECM is unsuccessful in turning ON the configurable function.
NOTE:
The DDR will display the parameter text description in TABLE 2 (ECM Output
Options) to identify the function assigned to AUXILIARY OUTPUT #6.
The DDEC III ECM supplies a switched ground to the AUXILIARY OUTPUT #6
circuit to turn ON the function assigned
FLASH CODE:
62
DDR DISPLAY:
(AUXILIARY OUTPUT #6) OPEN CIRCUIT
SAE J1587 CODE:
SID: 054 FMI: 4
Indicates that the function assigned to the Auxiliary Output #1 circuit output is open or is shorted to ground. This
diagnostic condition is detected when the Auxiliary Output #6 function Is OFF and the DDEC III ECM measures a low
voltage on the circuit output.
NOTE:
The DDR will display the parameter text description in TABLE 2 (ECM Output
Options) to identify the function assigned to AUXILIARY OUTPUT #6.
FLASH CODE:
62
DDR DISPLAY:
(AUXILIARY OUTPUT #7) SHORT TO BATTERY (+)
SAE J1587 CODE:
SID: 055 FMI: 3
Indicates that the function assigned to the Auxiliary Output #7 circuit output is shorted to battery (+). This diagnostic
condition is detected when the DDEC III ECM is unsuccessful in turning ON the configurable function.
NOTE:
The DDR will display the parameter text description in TABLE 2 (ECM Output
Options) to identify the function assigned to AUXILIARY OUTPUT #7.
The DDEC III ECM supplies a switched ground to the AUXILIARY OUTPUT #7
circuit to turn ON the function assigned
FLASH CODE:
62
DDR DISPLAY:
(AUXILIARY OUTPUT #7) OPEN CIRCUIT
SAE J1587 CODE:
SID: 055 FMI: 4
Indicates that the function assigned to the Auxiliary Output #1 circuit output is open or is shorted to ground. This
diagnostic condition is detected when the Auxiliary Output #7 function is OFF and the DDEC III ECM measures a low
voltage on the circuit output.
NOTE:
The DDR will display the parameter text description in TABLE 2 (ECM Output
Options) to identify the function assigned to AUXILIARY OUTPUT #7.
FLASH CODE:
62
DDR DISPLAY:
(AUXILIARY OUTPUT #8) SHORT TO BATTERY (+)
SAE J1587 CODE:
SID. 056 FMI: 3
Indicates that the function assigned to the Auxiliary Output #8 circuit output is shorted to battery (+). This diagnostic
condition is detected when the DDEC III ECM is unsuccessful in turning ON the configurable function.
NOTE:
The DDR will display the parameter text description in TABLE 2 (ECM Output
Options) to identify the function assigned to AUXILIARY OUTPUT #8.
Change 3 3-345.31