TM9-2320-363-20-1
CABLE TERMINALS AND CONNECTORS REPLACEMENT
ITERMINAL-TYPE
CABLE CONNECTORS
1.
STRIP CABLE INSULATION
EQUAL TO
2.
SLIDE INSULATOR
OVER CABLE.
DEPTH OF TERMINAL
WELL.
3.
INSERT CABLE INTO TERMINAL WELL, AND CRIMP.
4.
SLIDE INSULATOR
OVER CRIMPED
END OF TERMINAL.
IMALE CABLE CONNECTOR (WITH WASHER)l
1.
STRIP CABLE INSULATION
EQUAL TO DEPTH OF FERRULE WELL.
2.
SLIDE SHELL OVER CABLE.
3.
INSERT CABLE INTO TERMINAL WELL, AND CRIMP.
4.
PLACE C-WASHER
OVER CABLE AT CRIMPED
JUNCTION
AND SLIDE SHELL OVER C-WASHER
AND TERMINAL.
3-5