TM 9-2320-363-10
2-27.
OPERATE POWER TAKE-OFF (PTO) (ALL EXCEPT
M915A2) (Cont).
(5)
On M916A1 and M916A2, operate winch (paragraph 2-28).
(6)
On M917A1 and M917A1 w/MCS, operate hydraulic control
lever (TM 5-3805-264-14&P).
b.
Shut Down PTO.
(1)
On M916A1 and M916A2, release winch controls. If engine
rpm was raised, reduce rpm using throttle control switch.
(2)
On M917A1 and M917A1 w/MCS, place hydraulic control in
Neutral (N) (TM 5-3805-264-14&P).
(3)
OFF position.
On M917A1 and M917A1 w/MCS, place main light switch to
(4)
Place PTO switch to OFF position. PTO indicator light will go
out.
2-28.
OPERATE WINCH (M916A1 AND M916A2).
a . G e n e r a l .
(1)
M916A1 and M916A2 tractors are equipped with a full
hydraulic winch mounted on the frame behind the cab. The winch has a fail safe
spring-loaded brake that automatically sets any time the winch control valve is in neu-
tral or there is a power failure (hydraulic pressure drops to less than 200 psi).
(2)
The winch operates at 2100 psi hydraulic pressure from a
dual pump driven by a PTO on the transmission. The rated capacity of the winch is
45,000 lb (20,250 kg). For more information, refer to TM 5-725.
2-110