TM 9-2320-302-20
0157 00-2
AIR DRYER REPLACEMENT - CONTINUED
0157 00
REMOVAL - CONTINUED
NOTE
Assistance is needed to support air dryer while removing mounting hardware.
4.
Support air dryer (3) and remove four lock nuts (9), eight washers (10), and four screws (11) securing air dryer to frame
rail (12). Remove air dryer and discard lock nuts.
5.
If mounting plate (13) is damaged, remove two lock nuts (14), two screws (15), four washers (16), and mounting plate
(13). Discard lock nuts.
INSTALLATION
1.
If removed, install mounting plate (13), four washers (16), two screws (15), and new lock nuts (14).
2.
With assistance, install air dryer (3) on frame rail (12) with four screws (11), eight washers (10), and four new lock nuts
(9).
WARNING
Adhesives and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin
and clothing. To avoid injury or death, keep away from open fire and use in a well-ventilated area. If
adhesives or sealing compound gets on skin or clothing, wash immediately with soap and water.
Ensure air lines and fittings are clear of debris and excess pipe sealing compound does not enter air lines
or fittings. Failure to to follow this warning could result in injury to personnel or damage to equipment.
3.
Apply pipe sealing compound to pipe threads and install adapter (8), two bushings (7), and three elbows (6) on air dryer
(3).
11
3
10
14
16
13
12
16
15
9
10
9
10