DDEC TROUBLESHOOTING
7.1.25
Progressive Shift Configuration
Progressive shift configuration can be set with the DDR or programming station and can be used
to force shifting. It is also useful to limit engine r/min in certain gears, to force shifting to a higher
gear. Use Spec Manager to determine values to enter.
7.1.26
Rating Selections
Ratings can be selected with DDR or programming station. Selections are limited to ratings
available within the 6N4D group.
7.1.27
Top 2 (Eaton)
Top 2 can be set with the programming station. Two outputs are required - shift solenoid and
shift lockout. The transmission type is manual.
7.1.28
Transmission Type
Transmission type can be set with the programming station only. Choices at time of print (may be
limited by the application code) are listed in Table 7-5.
Transmission
Transmission
Transmission
00 Manual
14 Other Automatic
20 Rockwell RSX9-R
01 Allison Hydraulic
15 GE Statex III
21 Rockwell RS10
03 Voith
16 Autoshift / J1939
22 Rockwell RSX10
04 Z-F Ecomat
17 Rockwell RS9
23 Reserved - RSX10-C
09 Allison Electronic
18 Rockwell RSX9-A
-
12 Allison WT
19 Rockwell RSX9-B
-
Table 7-5
Available Transmission Selections
7.1.29
Vehicle Overspeed Parameters
Vehicle overspeed parameters can be set with the DDR or programming station. Customer
decided parameters log vehicle overspeed codes. The parameter is typically set for +3 mph and +5
mph greater than the current vehicle speed limit; e.g. vehicle speed limit 65. Maximum overspeed
limit is 68 and maximum speed no fuel is 70. Setting both to zero disables the function.
NOTE:
Remember to review these figures if Fuel Economy Incentive is activated.
7.1.30
Vehicle Speed Limiting
Vehicle speed limiting can be set with the DDR or programming station. Requires VSS set to Yes.
All information subject to change without notice.
6SE497 9709 Copyright © 1997 DETROIT DIESEL CORPORATION
7-11