TM 9-2320-302-20
0099 00-2
WATER LEVEL SENSOR REPLACEMENT - CONTINUED
0099 00
INSTALLATION
WARNINGS
Adhesives and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and
clothing. To avoid injury or death, keep away from open fire and use in a well-ventilated area. If adhesives
or sealing compound contacts skin or clothing, wash immediately with soap and water.
1.
Lightly coat threads of adapter (5) and water level sensor (4) with pipe sealing compound. Install adapter and water level
sensor in engine block (6).
2.
Install wire (3) on water level sensor (4) with new lock washer (2) and nut (1).
3.
Fill cooling system (WP 0041 00).
END OF WORK PACKAGE
1
2
3
4
5
6