TM 9-2320-273-20TRANSMISSION.6-9. OIL SERVICE (Continued).LOCATION/lTEMACTIONREMARKSA. DRAINING OIL (Continued).1. Dipstick (4).Remove.2. Drain plug (6) anda. Unscrew and remove.O-ring (7).b. Throw away O-ring.c. Allow oil to drain out.d. Inspect magnetic base ofIf there are large metal particlesplug.notify Direct Support Mainte-n a n c e .e. Install new O-ring (7) ondrain plug (6).f. Screw in plug and tighten,A-1. TAKING OIL SAMPLE FOR ANALYSISNOTEBefore beginning this task check trans-mission oil level according to operator’smanual (TM 9-2320-273-10).Start engine (see TM 9-2320-273-10),warm vehicle to normal operatingrange and stop engine.1. Draincock (16)a. Unscrew and loosen.When taking a sample, first use acontainer to drain a small amountof oil to clean the valve assembly.b. When completed with task1., use the proper bottleand take oil sample fromthe transmission drain valve(see TB 43-0210).c. Check oil level to insureproper level after sampling.6-12Change 2