TM 9-2320-273-20
SENDING UNITS, SWITCHING DEVICES, AND WINTERIZATION KIT.
5-87. WINTERIZATION KIT CIRCUIT BREAKERS, BOX, AND RECEPTACLE
MAINTENANCE (Continued).
LOCATION/lTEM
ACTION
REMARKS
1. Four screws (7) and
Remove and lift out inner
Open outer cover to
washers (8).
panel (6).
gain access to (6),
(7), and (8).
2. Two screws (1) or (4).
Remove and lift off wires.
Screws (1) if 15 amp
breaker; screws (4) if
30 amp breaker. Mark
wires for location.
3. Circuit breaker (2)
Remove by pulling out.
Circuit breakers are the
or (3).
plug in type. Item (2)
15 amp; Item (3) 30
amp.
4. Circuit breaker
Install by pushing into
Be sure breaker is
(2) or (3).
position.
securely snapped in.
5. Two screws (1) or (4).
Place wires into position
Be sure to reattach
on circuit breaker and
wires as marked in step 2.
secure with screws.
6. Inner panel (6).
Set into position in box
(5) and attach with four
screws (7) and washers (8).
5-319