TM 9-2320-273-20
SENDING UNITS, SWITCHING DEVICES, AND WINTERIZATION KIT.
5-87. WINTERIZATION KIT CIRCUIT BREAKERS, BOX, AND RECEPTACLE MAINTENANCE.
THIS TASK COVERS: (APPROXIMATE TIME REQUIRED FOLLOWS TASK DESCRIPTION. )
a. Removal of Circuit Breaker (es).
(15)
d. Removal of Circuit Breaker Box and Receptacle,
(60)
b. Installation of Circuit Breaker (es). (15)
e. Installation of Circuit Breaker Box and Receptacle.
(60)
c. Operational Check.
(15)
f. Operational Check
(30)
195 Minutes
Total.
INITIAL SETUP
EQUIPMENT CONDITION
APPLICABLE CONFIGURATIONS
PARAGRAPH
CONDITION DESCRIPTION
All.
5-37A.
Batteries Disconnected.
TEST EQUIPMENT
None.
SPECIAL TOOLS
None.
MATERIALS/PARTS (P/N)
30 Amp Circuit Breaker (1).
15 Amp Circuit Breaker (3).
PERSONNEL REQUIRED
One (MOS-63B20).
REFERENCES (TM)
TM 9-2320-273-10.
TM 9-2320-273-20P.
TROUBLESHOOTING REFERENCES
Table 5-14.
SPECIAL ENVIRONMENTAL CONDITIONS
Vehicle Parked on Level Ground.
GENERAL SAFETY INSTRUCTIONS
Engine Off.
Transmission in Neutral.
Park Brake Set.
110 VAC Cable Disconnected From
Power Source and Receptacle.
All Breakers Set to OFF.
5-318