TM 9-2320-273-20
ETHER QUICK-START SYSTEM.
4-32. ATOMIZER MAINTENANCE (Continued).
LOCATION/lTEM
ACTION
REMARKS
NOTE
Coolant temperature must be below 50°F
or solenoid valve will not function.
B. INSTALLATION AND OPERATIONAL CHECK.
2. Ether tube (3).
lNSTRUMENT PANEL/
3. Ether button.
4. Atomizer (2).
INSTRUMENT PANEL/
5. Engine run switch.
6. Atomizer (2).
7. Ether tube (3).
Screw on atomizer (2).
Push (2nd mechanic).
Engine run switch must be ON
Observe ether mist from
If mist is not observed, check
atomizer (2) (2nd mechanic).
ether temperature switch
(para 5-74), ether cylinder
(para 4-30), solenoid valve
(para 4-31), and ether tube
(para 4-33).
Engine run switch OFF
(2nd mechanic).
a. Remove from ether tube
(3).
b. Screw into crossover tube
(1).
Screw into atomizer (2).
4-110