DIRECT SUPPORT MAINTENANCE INTRODUCTION
A/C BINARY SWITCH REPLACEMENT - CONTINUED

Repair Parts For Air Conditioner And Stowage Box Kit Model 7336 And Het Model 1070, 8X8 Page Navigation
  247    248    249    250    251  252  253    254    255    256    257  
img
. . . . .
TB 9-2320-360-13&P-1
A/C BINARY SWITCH REPLACEMENT
0044 00
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Materials/Parts - Continued
Maintenance Level
Direct Support
Tags, Identification (Item 14, WP 0061 00)
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanic (Item 12, WP 0060 00)
Wheels chocked (TM 9-2320-360-10)
Materials/Parts
Hood opened (TM 9-2320-360-10)
Sealing Compound (Item 2, WP 0061 00)
REMOVAL
WAR N I N G
Use care to prevent refrigerant from touching your skin or eyes. Liquid refrigerant, when exposed to air,
quickly evaporates and will freeze skin or eye tissues. Be sure to wear proper protective goggles and nonleather gloves
when servicing Air Conditioning systems to prevent personal injury. Serious injury or blindness may result if you
come in contact with liquid refrigerant.
Refrigerant R-134a A/C systems should not be pressure tested or leak tested with compressed air. Combustible
mixtures of air and R-134a may form, resulting in a fire or explosion, which could cause personnel injury or
death.
0044 00-1