• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
A/C BLOWER OPERATES BUT NO COLD AIR FROM A/C DUCTS
A/C BLOWER OPERATES BUT NO COLD AIR FROM A/C DUCTS - Continued

Repair Parts For Air Conditioner And Stowage Box Kit Model 7336 And Het Model 1070, 8X8 Page Navigation
  119    120    121    122    123  124  125    126    127    128    129  
img
. .
TB 9-2320-360-13&P-1
WARN I N G
Jewelry can catch on equipment and cause injury or short across electrical circuit and cause severe
burns or electrical shock. Remove rings, bracelets, watches, necklaces, and any other jewelry
before working around HET Tractor.
VISUAL INSPECTION
(1) Inspect area around A/C intake filter.
(a) If A/C intake filter is blocked with
debris, clear debris. Verify repair,
go to Step 13 of this fault.
(2) Remove two screws and doghouse
door (WP 0028 00).
(3) Inspect A/C intake filter for blockage,
dust, and debris.
(a) If A/C intake filter is blocked with
dust or debris, remove A/C filter
(WP 0028 00) and clean or replace
as required. Verify repair, go to
Step 13 of this fault.
(b) If A/C intake filter is free from
blockage and debris, go to Step 2
of this fault.
HETF00444
0017 00-3