Table 2. Operator's Preventive Maintenance Checks and Services (During).
Table 3. Operator's Preventive Maintenance Checks and Services (Weekly) - Continued.

Repair Parts For Air Conditioner And Stowage Box Kit Model 7336 And Het Model 1070, 8X8 Page Navigation
  62    63    64    65    66  67  68    69    70    71    72  
img
. .
TB 9-2320-360-13&P-1
OPERATOR'S PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0007 00
Table 3. Operator's Preventive Maintenance Checks and Services (Weekly).
Location
Item
Not Fully Mission
No.
Interval
Item to Check/Service
Procedure
Capable if:
a. Ensure A/C control switch is in OFF posi-
3
Weekly
A/C intake filter and
tion (WP 0007 00).
A/C evaporator con-
densation drain
b. Remove two screws (1) and open dog-
house door (2).
c. Check A/C intake filter (3). Perform steps
d. through f. if filter is dirty or clogged.
d. Release spring loaded clips (4) and remove
A/C intake filter (3).
e. Wash A/C intake filter (3) with fresh
water, or vacuum, or blow dust from filter.
f. Install A/C intake filter (3) and close
spring loaded clips (4).
HETACF00207
0007 00-3