TB 9-2320-335-13&P
7-10. PROPORTIONING VALVE AND DIFFERENTIAL VALVE REPLACEMENT (Cont'd)
d. Proportioning Valve Installation
1.
Install proportioning valve (16) and proportioning valve bracket (12) on bracket (10) with screw
(11), washer (13), and locknut (14). Tighten locknut (14) to 22 lb-ft (30 Nm).
2.
Connect two brake lines (15) to bottom of proportioning valve (16).
3.
Connect two brake lines (17) to top of proportioning valve (16).
2
9
3
1
4
3
5
8
7
6
5
10
17
11
16
15
12
14
13
FOLLOW-ON TASKS: Lower and secure hood (TM 9-2320-387-10).
Connect battery ground cables (TM 9-2320-387-24-1).
7-25