• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. Operator Preventive Maintenance Checks and Services (PMCS) - Continued.
A/C AIR FILTER REPLACEMENT

Crew Protection Kit For M915A3P1, M915A2P1, M916A3P1, M917A2P1, M915A401, M917A1P1, M916A1P1, And M916A2P1 - 3 Page Navigation
  21    22    23    24    25  26  27    28    29    30    31  
img
TB 9-2320-302-13&P-3
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0009 00
Table 1. Operator Preventive Maintenance Checks and Services (PMCS) - Continued.
Location
Item To
Item
Not Fully Mission
Check/
No.
Interval
Procedure
Capable If:
Service
a. Hood opened (TM 9-2320-363-10).
5
Weekly
Condenser
b.Inspect condenser for damage and Condenser is damaged, or mounting
loose or missing mounting hardware.  bolts are loose or missing and A/C is
required for mission.
c. Inspect condenser for leaks. Leaks can Leaks are evident and A/C is required
be identified by oil residue on fittings for mission.
or on condenser core.
d.Inspect A/C hoses for damage and A/C hoses are damaged or have loose or
loose or missing mounting hardware.  missing mounting hardware and A/C is
required for mission.
e. Inspect A/C hoses for leaks. Leaks Leaks are evident and A/C is required
can be identified by oil residue on fit- for mission.
tings or along hose.
449-056
CONDENSER
A/C HOSES AND FITTINGS
END OF WORK PACKAGE
0009 00-8


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.