Table 1. Operator Preventive Maintenance Checks and Services (PMCS) - Continued.
Table 1. Operator Preventive Maintenance Checks and Services (PMCS) - Continued.

Crew Protection Kit For M915A3P1, M915A2P1, M916A3P1, M917A2P1, M915A401, M917A1P1, M916A1P1, And M916A2P1 - 3 Page Navigation
  16    17    18    19    20  21  22    23    24    25    26  
img
TB 9-2320-302-13&P-3
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0009 00
Table 1. Operator Preventive Maintenance Checks and Services (PMCS) - Continued.
Location
Item To
Item
Not Fully Mission
Check/
No.
Interval
Procedure
Capable If:
Service
Interior of
Cab
a. Inspect evaporator assembly for dam- Evaporator assembly is damaged or has
2
Weekly
Evaporator
aged and loose or missing mounting loose or missing mounting hardware
Assembly
and A/C is required for mission.
hardware.
b.Inspect RFI filter for damaged and RFI filter is damaged or has loose or
loose or missing mounting hardware.  missing mounting hardware and A/C is
required for mission.
c. Inspect A/C hoses and electrical har- A/C hoses or electrical harness are dam-
ness for damage and loose or missing aged or have loose or missing mounting
hardware and A/C is required for mis-
mounting hardware.
sion.
d.Inspect A/C hoses for leaks. Leaks Leaks are evident and A/C is required
can be identified by oil residue on fit- for mission.
tings or along hose.
EVAPORATOR
A/C HOSES
RFI FILTER
ASSEMBLY
AND FITTINGS
ELECTRICAL HARNESS
449-051
A/C FILTER ELEMENT
DRAIN TUBES
0009 00-3