TB 9-2320-302-13&P-3
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0009 00
Table 1. Operator Preventive Maintenance Checks and Services (PMCS) - Continued.
Location
Item To
Item
Not Fully Mission
Check/
No.
Interval
Procedure
Capable If:
Service
Outside of
Cab Left
Side
a. Inspect receiver/dryer unit for dam- Receiver/dryer unit is damaged or has
3
Weekly
Receiver/
aged and loose or missing mounting loose or missing mounting hardware
Dryer Unit
and A/C is required for mission.
hardware.
b.Inspect receiver/dryer unit for leaks. Leaks are evident and A/C is required
Leaks can be identified by oil residue for mission.
on fittings.
c. Inspect A/C hoses and electrical har- A/C hoses or electrical harness are dam-
ness for damage and loose or missing aged or have loose or missing mounting
hardware and A/C is required for mis-
mounting hardware.
sion.
d.Inspect A/C hoses for leaks. Leaks Leaks are evident and A/C is required
can be identified by oil residue on fit- for mission.
tings or along hose.
ELECTRICAL HARNESS
A/C HOSES AND FITTINGS
RECEIVER/DRYER
449-053
0009 00-5