TB 9-2320-302-13&P-1
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0009 00
Location
Item To
Check/
Item
Not Fully Mission
No.
Interval
Procedure
Capable If:
Service
7
Before
Floor /Fire-
a. Inspect right side floor and firewall Any panel or armor plate is damaged,
wall Armor
armor panels for damage or loose or bent out of shape, misaligned, loose or
(Right Side)
missing mounting hardware.
missing, or mounting bolts are loose or
missing.
b. Inspect right side floor and firewall Any corrosion where area is unsound
armor panels for areas of rust or cor- and small pin holes are present, or a
rosion.
rusted through condition is present.
c. Inspect right side floor and firewall Any cracks that are longer than 1" or
armor panels for cracks near or elon- two consecutive bolt holes that are elon-
gation of bolt holes.
gated.
d. Inspect right side floor and firewall Any complete penetration of the armor
armor panels for any holes or gouges. (hole in the armor) or multiple gouges
1/4" or deeper within 3" of each other.
FIREWALL ARMOR
FLOOR ARMOR
417-257
8
Weekly
Front Sus-
Inspect front suspension springs and
Any cracks, breaks, or loose hardware
pension
mounting hardware for cracks, breaks,
or damage to suspension springs is
or loose or missing hardware and/or
noted.
shackles. Notify your supervisor of any
damage found.
9
Weekly
Cab Mounts
Inspect cab mounts for evidence of dete- Deterioration, over compression, or
rioration, over compression or loose
loose mounting hardware is noted.
mounting hardware. Notify your super-
visor of any damage or looseness found.