TB 9-2320-279-13&P-4
0041
Table 2. Hydraulic Reservoir Servicing.
EXPECTED TEMPERATURES
ABOVE 60F ABOVE 15F
40 to -15F
40 to -50F
ITEM
CAPACITIES
INTERVAL
(-9C)
(-9C)
(4 to -26C )
(4 to -46C )
Hydraulic
135 qt.
OE/HDO-30
OE/HDO-10
OE/HDO-10
OEA
A-Annual
Reservoir
(127.71 L)
MIL-
MIL-
MIL-
MIL-
(1 year)
PRF-2104
PRF-2104
PRF-2104
PRF-46167
(Note 1)
(Note 1)
(Note 2)
(Notes 2 and
3)
NOTE
1. OE/HDO-30 must be used only when temperatures are consistently above 60F (16
C).
2. Refer to FM 9-207 (WP 0079) for arctic operation.
3. OEA must be used when temperatures are consistently below 0F (-18C).
END OF WORK PACKAGE