TB 9-2320-279-13&P-4
0032
TUBE
TUBE
FITTING
FITTING
HOSE
HOSE
2900
2901
Figure 12.
4. Install hydraulic flow tester output hose to hydraulic hose 2900.
WARNING
Excessive noise levels are present any time the heavy-duty winch, crane, or retrieval system
is operating. Wear single hearing protection (earplugs or equivalent) while working around
equipment when it is running. Failure to comply may result in injury or death to personnel.
Seek medical aid should you suspect a hearing problem.
5. Start engine (refer to TM 9-2320-279-10).
6. Set PTO ENGAGE switch to ON position. (WP 0015)
NOTE
All hydraulic tests must be performed with hydraulic oil reservoir at least warm to the touch and
at high idle.