TB 9-2320-279-13&P-4
0029
Winch is bypassed for this test, and cable will not pay out or reel in.
When performing test, winch control valve must be fully engaged or test readings will be faulty.
Relief pressure is obtained when flow reading drops off and pressure reading on gauge does
not increase further.
8. Set heavy-duty winch control station HIGH IDLE ON/OFF switch to ON position. (WP 0015)
9. Have assistant operate winch IN manual control, while closing off load valve on hydraulic flow tester until relief
10. Note reading on pressure gauge when pressure relief is obtained.
11. Have assistant release winch control.
12. Set heavy-duty winch control station HIGH IDLE ON/OFF switch to OFF position. (WP 0015)
13. Set PTO ENGAGE switch to OFF position. (WP 0015)
14. Shut OFF engine (refer to TM 9-2320-279-10).
CONDITION/INDICATION
Is 2,850 psi (19 650 kPa) measured at heavy-duty winch motor?
DECISION
No - Replace heavy-duty winch control valve (relief valve faulty). (WP 0072)Test 2 - Is 2,850 psi (19 650 kPa)
measured at heavy-duty winch motor?
Yes - Replace heavy-duty winch motor. (WP 0068)Test 3 - Does winch pull load?
TEST 2 - Is 2,850 psi (19 650 kPa) measured at heavy-duty winch motor?
WARNING
Excessive noise levels are present any time the heavy-duty winch, crane, or retrieval system
is operating. Wear single hearing protection (earplugs or equivalent) while working around
equipment when it is running. Failure to comply may result in injury or death to personnel.
Seek medical aid should you suspect a hearing problem.
NOTE
This procedure checks hydraulic pump output pressure after replacing heavy-duty winch relief
valve.
If hydraulic flow tester was disconnected, reconnect tester on hydraulic hoses 2900 and 2901
per previous test.
0029-4