CONDITION/INDICATION
Does winch operate normally IN and OUT with remote control?
DECISION
No - Test 2 - Does winch operate normally after warming hydraulic fluid for 20 minutes?
Yes - Notify Supervisor.
TEST 2 - Does winch operate normally after warming hydraulic fluid for 20 minutes?
NOTE
If outside temperature is 0F (-17C) or lower, hydraulic fluid may not flow easily.
1. Operate engine (Refer to TM9-2320279-10) for 20 minutes with PTO ENGAGE switch set to ON to bring
hydraulic fluid up to operating temperature.
Figure 2.
CONDITION/INDICATION
Does winch operate normally after warming hydraulic fluid for 20 minutes?
DECISION
No - Problem not corrected. Notify Supervisor.
Yes - Problem corrected.
END OF WORK PACKAGE