CENTER BLAST DEFLECTOR REPLACEMENT - CONTINUED
CENTER BLAST DEFLECTOR REPLACEMENT - CONTINUED

Maintenance Manual For Crew Protection Kit For M977 Series Hemtt Page Navigation
  115    116    117    118    119  120  121    122    123    124    125  
img
.
TB 9-2320-279-13&P-2
CENTER BLAST DEFLECTOR REPLACEMENT - CONTINUED
0029 00
CLEANING AND INSPECTION
Clean and inspect all parts IAW General Maintenance Instructions (WP 0011 00).
INSTALLATION
WARN I N G
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can cause lung irritation.
Contact with skin can cause dermatitis. Wear gloves and safety goggles and use product in a well-ventilated
area away from open flame. If ingested, keep individual calm and seek medical attention. DO NOT induce
vomiting. If contact with skin or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW
local policy and ordinances. Failure to follow this warning may cause injury to personnel.
1.
If removed, install center blast deflector brackets (14 and 15) with forward surface against rear edge of crossmember
and studs facing the ground. Tighten two bolts (12) and bolts (13).
2.
Apply thread adhesive to four bolts (5).
12 (HIDDEN)
13 (HIDDEN)
14
15
417-072
0029 00-3