TM 9-2320-363-34-2CONTROLVALVEREPLACEMENTANDREPAIR(CONT)7.8.W A R N I N GParts are under spring tension. Release tension slowly to prevent personalinjury.C A U T I O NIDo not use magnets to remove valve bodies to prevent damage to equipment.Magnetized valve bodies may not work properly.NOTERecord each notch on adjusting ring that touches retainer pin.PRESS ADJUSTING RING (11) INWARD AND REMOVE RETAINER PIN (12) FROM MODULATORVALVE BODY (2).REMOVE ADJUSTINGVALVE BODY (2).RING (11), SPRING (13), VALVE (14), AND PIN (15)FROM MODULATOR14-78