TM 9-2320-363-34-2
5.
TEST STATOR (10) AS FOLLOWS:
A. CONNECT ONE OHMMETER LEAD TO BARE METAL SURFACE ON STATOR
LAMINATION (11). CONNECT OTHER LEAD TO EACH OF THREE STATOR (10)
TERMINALS. HIGH RESISTANCE READING SHOULD BE OBTAINED EACH TIME. IF
THERE IS NO READING OR OHMMETER READS ZERO, REPLACE STATOR (10).
B. CONNECT OHMMETER LEADS AS FOLLOWS (NOTE EACH READING):
A AND B
A AND C
B AND C
EACH MEASUREMENT SHOULD BE APPROXIMATELY EQUAL. IF DIFFERENCE IS GREAT
BEIVVEEN ANY TWO READINGS, REPLACE STATOR (10).
Use general cleaning methods to clean all parts (page 2-30).
I N S P E C T I ON
1.
INSPECT FOR BURNED OR CHARRED COMPONENTS (I.E., STATOR, ROTOR, ETC.).
2.
INSPECT BEARINGS IN ACCORDANCE WITH TM 9-214.
3.
INSPECT ALL PARTS FOR WEAR OR DAMAGE.
Repair of the alternator is the replacement of all worn or defective parts.
13-11