TM 9-2320-363-20-1
Section 4
TROUBLESHOOTING CHARTS
FLASH CODE:
34
DDR DISPLAY:
TURBO BOOST SENSOR INPUT VOLTAGE LOW
SAE J1587 CODE:
PID: 102 FMI: 4
Indicates that the engine Turbo Boost Sensor (TBS) input to the ECM has dropped below 5% (normally < 0.25 volts)
of the sensor supply voltage. This diagnostic condition is typically:
(1)
open sensor signal circuit
(2)
open sensor +5 volt supply circuit
(3)
sensor signal is shorted to the sensor return circuit or to ground
(4)
sensor +5 volt supply is shorted to sensor return circuit
FLASH CODE:
35
DDR DISPLAY:
OIL PRESSURE SENSOR INPUT VOLTAGE HIGH
SAE J1587 CODE:
PID: 100 FMI: 3
Indicates that the engine Oil Pressure Sensor (OPS) input to the ECM has exceeded 95% (normally > 4.75 volts) of
the sensor supply voltage. This diagnostic condition is typically:
(1)
open sensor return circuit
(2)
sensor signal circuit is shorted to the sensor +5 volt supply
FLASH CODE:
36
DDR DISPLAY:
OIL PRESSURE SENSOR INPUT VOLTAGE LOW
SAE J1587 CODE:
PID: 100 FMI: 4
Indicates that the engine Oil Pressure Sensor (OPS) input to the ECM has dropped below 5% (normally < 0.25 volts)
of the sensor supply voltage. This diagnostic condition is typically:
(1)
open sensor signal circuit
(2)
open sensor +5 volt supply circuit
(3)
sensor signal is shorted to the sensor return circuit or to ground
(4)
sensor +5 volt supply is shorted to sensor return circuit
FLASH CODE:
37
DDR DISPLAY:
FUEL PRESSURE SENSOR INPUT VOLTAGE HIGH
SAE J1587 CODE:
PID: 94 FMI 3
Indicates that the engine Fuel Pressure Sensor (FPS) input to the ECM has exceeded 95% (normally > 4.75 volts) of
the sensor supply voltage. This diagnostic condition is typically:
(1)
open sensor return circuit
(2)
sensor signal circuit is shorted to the sensor +5 volt supply
FLASH CODE:
38
DDR DISPLAY:
FUEL PRESSURE SENSOR INPUT VOLTAGE LOW
SAE J1587 CODE:
PID: 94 FMI: 4
Indicates that the engine Fuel Pressure Sensor (FPS) input to the ECM has dropped below 5% (normally < 0.25
volts) of the sensor supply voltage. This diagnostic condition is typically:
(1)
open sensor signal circuit
(2)
open sensor +5 volt supply circuit
(3)
sensor signal is shorted to the sensor return circuit or to ground
(4)
sensor +5 volt supply is shorted to sensor return circuit
Change 3 3-345.25