Table 3-1.
Troubleshooting
(Cont)
Malfunction
Test or Inspection
Corrective Action
5.
MEDIUM SPEED DOES
NOT
Step
1.
Disconnect
fan control
l
Step
2.
Disconnect
l
ELECTRICAL SYSTEM (CONT)
Standard Heater Circuits (Cont)
OPERATE.
lead 98E from heater fan control. Check
for +12
VDC
at heater
connector
(C) with heater
fan control in medium
mode.
If +12
VDC
is present,
go to step 2. If no voltage
is present,
replace
heater fan control (page 4-190).
lead 98E
from resistor block. Check for +12
VDC
at lead 98E.
If +12
VDC
is present,
go to step 3. If no voltage
is present,
repair lead 98E (page 3-2).
Step 3.
Disconnect leads 98E and 98F from heater
fan
resistor
block. Check
for
continuity
between
contacts
of heater
resistor block.
.
If no continuity is indicated,
replace
resistor
block (notify direct
support maintenance).
6.
LOW
SPEED
DOES
NOT
OPERATE.
Step
1.
Disconnect
fan control
l
Step
2.
Disconnect
lead 98Y.
l
Step 3.
Disconnect
lead 98Y
from heater fan control. Check
for +12
VDC at
heater
connector
(E) with heater fan
control
in
low mode.
If +12
VDC
is present,
go
to
step
2.
If no voltage
is
present,
replace
heater fan control (page
4-190).
lead 98Y
from heater fan resistor block. Check
for +12
VDC
at
If +12
VDC
is present,
go to step 3. If no voltage
is present,
repair lead 98Y
(page 3-2).
leads 98Y
and 98E
from heater fan resistor
block.
Check for
continuity
between
contacts
of resistor block.
.
If no continuity is indicated,
replace
heater
fan resistor block
(notify direct support maintenance).