Table 3-1.
Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
ELECTRICAL SYSTEM (CONT)
Standard Heater Circuits (Cont)
Step
5.
Disconnect
lead 98T from heater fan motor. Check for +12
VDC
at lead 98.
.
If no voltage is present, replace
heater fan high relay
(pages
4-197,
4-198).
3.
HIGH
SPEED
DOES
NOT
OPERATE.
Step
1.
Disconnect
lead 98L from heater fan control. Check
for +12
VDC
at
connector
(D)
with
heater
fan
control
in high mode.
.
If +12 VDC
is present, go to step 2. If no voltage
is present,
replace
heater fan control (page
4-190).
Step
2.
Disconnect
heater fan high relay from connector.
Check
for +12 VDC
at
connector
85 with heater fan control in high mode.
.
If +12 VDC
is present, go to step 3. If no voltage
is present,
repair lead 98L (page 3-2).
Step 3.
Disconnect
heater fan high relay from connector.
Check for continuity
between
connector
86 and ground.
.
If continuity is indicated, go to step 4. If no continuity is
indicated,
repair ground lead (page
3-2).
Step 4.
Disconnect
lead 98T from heater fan motor. Check
for +12
VDC
at lead 98T.
.
If no voltage is present, replace
heater
fan high relay
(pages
4-197,
4-198).
4.
MEDIUM-HIGH
SPEED
DOES
NOT
OPERATE.
Step
1.
Disconnect
lead 98F from heater fan
fan control connector
(F) with heater
.
If +12
VDC
is present,
control. Check
for +12
VDC
at heater
fan control in medium-high
mode.
go to step 2. If no voltage
is present,
replace
heater
fan
control
(page
4-190).
Step
2.
Disconnect
lead
98F
from
heater
fan
resistor
block. Check
for +12 VDC
at
lead 98F.
.
If no voltage is present,
repair lead 98F
(page
3-2).
3-73