TM 9-2320-363-10
2-39.
OPERATE IN EXTREME COLD (Cont).
Battery voltage must be the same as voltage indicated
on heater hand pump lever. Incorrect voltage may cause
damage to equipment.
(5)
Connect cable (11) to connector (12) and batteries.
(6)
Close fuel regulator (6).
(7)
Squeeze ignition switch (4) on pump lever (5) and actuate
pump.
(8)
After three or four strokes, open fuel regulator (6) 1/2 to 1 turn
while continuing to pump.
(9)
Adjust fuel regulator (6) until pulsating sounds come in equal
intervals. Stop pumping.
(10)
After three to five minutes, adjust fuel regulator (6) until pul-
sating evens out.
(11)
Disconnect cable (11) from connector (12) and batteries.
2-129