TM 9-2320-303-10
Table 2-1. Preventive Maintenance Checks and
Services (PMCS) for M915A4 (Con't).
Location
Item To
Check/
Not Fully Mission
Item No.
Interval
Service
Procedure
Capable If:
45
Weekly
Ether -
WARNING
Quick
Start
System
Ether is highly flammable and explosive. DO
NOT perform ether quick-start system checks
or inspections while smoking or near fire,
flame, or sparks. Failure to follow this warning
may cause a fire and explosion, causing
serious injury or death to personnel.
Check
for
loose
connections and damage
to
lines,
fittings,
and
canister. Be alert for the
odor of leaking ether.
Damage
or
leakage
is
evident.
46
Weekly
Wind-
shield
Washer
Reser-
voir
Check level of fluid in
reservoir
located
in
engine
compartment
below driver windshield
on left firewall. Add
windshield
cleaning
compound
(Item
2,
Appendix D) as required.
47
Weekly
Front
WARNING
Wheel
and Tires
Operating truck with an underinflated or
defective tire may lead to tire failure and loss of
steering control. Damage to equipment or
injury to personnel may result.
a. Check pressure in tires
and adjust as required:
Empty - 85 psi (586
kPa)
Loaded - 105 psi (724
kPa)
b. Ensure all wheel stud
lug
nuts
are
tight,
using wheel stud lug
nut
wrench
and
handle.
b. Two or more wheel studs
are missing or lug nuts are
loose.
c. Check
wheel
for
cracks,
breaks,
or
bends.
c. Wheel is cracked, broken,
or bent.
2-51