TM 9-2320-302-34
0049 00-9
WATER PUMP REPAIR - CONTINUED
0049 00
ASSEMBLY - CONTINUED
WARNING
Adhesives and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and
clothing. To avoid injury or death, keep away from open fire and use in well-ventilated area. If adhesive or
sealing compound gets on skin or clothing, wash immediately with soap and water
CAUTION
Use care when applying sealing compound. Too much can cause damage to sealing surface.
Wait four (4) hours after applying sealing compound to allow for drying. Water pump shaft must remain
vertical and must not be rotated or moved to prevent damage to equipment. Do not pressure test seal for
at least four (4) hours.
15.
Apply one drop of sealing compound to water seal and water pump shaft contact area (25). Wipe off excess with a clean
rag.
16.
Apply a small amount of lubricating oil to water seal and water pump shaft contact area (25).
25