W T E C I I I E L E C T R O N I C C O N T R O L S T R O U B L E S H O O T I N G M A N U A L
DIAGNOSTIC CODES
0011 00-38
34
(0011 00-77)
12
Factory calibration compatibility
number wrong
Yes(5)
DNS, SOL OFF (hydraulic default), DNA
13
Factory calibration block checksum
Yes(5)
DNS, SOL OFF (hydraulic default), DNA
14
Power off block checksum
No
Use previous location, or factory
calibration and reset adaptive, DNA
15
Diagnostic queue block checksum
No
Use previous location, or clear diagnostic
queue, DNA
16
Real time block checksum
Yes
DNS, SOL OFF (hydraulic default), DNA
17
Customer modifiable constants
checksum
Yes(5)
DNS, SOL OFF (hydraulic default), DNA
35
(0011 00-79)
00
Power interruption (code set after
power restored)
No
None (hydraulic default during
interruption)
16
Real time write interruption
Yes
DNS, SOL OFF (hydraulic default), DNA
36
(0011 00-80)
00
Hardware/software not compatible
Yes (2)
DNS, SOL OFF (hydraulic default), DNA
01
TID not compatible with hardware/
software
No(2)
Use TIDCAP cal
02
TID did not complete
No
Use TIDCAP cal, code 42 XX or 69 XX
may be logged
42
12
Short-to-battery, A solenoid circuit
Yes
DNS, SOL OFF, DNA
(0011 00-82)
13
Short-to-battery, B solenoid circuit
Yes
DNS, SOL OFF, DNA
14
Short-to-battery, C solenoid circuit
Yes
DNS, SOL OFF, DNA
15
Short-to-battery, D solenoid circuit
Yes
DNS, SOL OFF, DNA
16
Short-to-battery, E solenoid circuit
Yes
DNS, SOL OFF, DNA
21
Short-to-battery, F solenoid circuit
No
Lockup inhibited, DNA
22
Short-to-battery, G solenoid circuit
Yes
DNS, SOL OFF, DNA
23
Short-to-battery, H solenoid circuit
No
Differential lock inhibited (3070 only),
retarder inhibited
24
Short-to-battery, J solenoid circuit
No
Low and 1st inhibited
26
Short-to-battery, N solenoid circuit
No
Low and 1st inhibited, allow retarder
44
(0011 00-86)
12
Short-to-ground, A solenoid circuit
Yes
DNS, SOL OFF (hydraulic default), DNA
13
Short-to-ground, B solenoid circuit
Yes
DNS, SOL OFF (hydraulic default), DNA
14
Short-to-ground, C solenoid circuit
Yes
DNS, SOL OFF (hydraulic default), DNA
15
Short-to-ground, D solenoid circuit
Yes
DNS, SOL OFF (hydraulic default), DNA
16
Short-to-ground, E solenoid circuit
Yes
DNS, SOL OFF (hydraulic default), DNA
21
Short-to-ground, F solenoid circuit
No
Lockup inhibited, DNA
22
Short-to-ground, G solenoid circuit
Yes
DNS, SOL OFF (hydraulic default), DNA
Table 52. WT Series Diagnostic Codes (Continued)
Main
Code
Sub-
code
Description
CHECK
TRANS
Light
Inhibited Operation
Description