DIAGNOSTIC CODES
W T E C I I I E L E C T R O N I C C O N T R O L S T R O U B L E S H O O T I N G M A N U A L
0011 00-37
23
(0011 00-62)
12
Primary shift selector or RSI link fault
No
Hold in last valid direction. May cause
cateye display.
13
Primary shift selector mode function
fault
No
Mode change not permitted
14
Secondary shift selector or RSI link
fault
No
Hold in last valid direction. May cause
cateye display.
15
Secondary shift selector mode
function fault
No
Mode change not permitted
16
Shift Selector display line fault
No
None. May cause cateye display.
24
12
Sump fluid temperature, cold
Yes
DNS, lock in neutral
(0011 00-64)
23
Sump fluid temperature, hot
No
No upshifts above a calibration range
25
(011 00-69)
00
Output speed sensor, detected at
0 output rpm, Low
Yes (1)
DNS, lock in current range (Low), DNA
11
Output speed sensor, detected at
0 output rpm, 1st
Yes (1)
DNS, lock in current range (1st), DNA
22
Output speed sensor, detected at
0 output rpm, 2nd
Yes (1)
DNS, lock in current range (2nd), DNA
33
Output speed sensor, detected at
0 output rpm, 3rd
Yes (1)
DNS, lock in current range (3rd), DNA
44
Output speed sensor, detected at
0 output rpm, 4th
Yes (1)
DNS, lock in current range (4th), DNA
55
Output speed sensor, detected at
0 output rpm, 5th
Yes (1)
DNS, lock in current range (5th), DNA
66
Output speed sensor, detected at
0 output rpm, 6th
Yes (1)
DNS, lock in current range (6th), DNA
77
Output speed sensor, detected at
0 output rpm, Reverse range
Yes (1)
DNS, lock in current range (R), DNA
26
00
Throttle source not detected
No
Use throttle default values, DNA
(0011 00-71)
11
Engine coolant source not detected
No
Use default value of 18°C (0°F)
32
00
C3 pressure switch open, Low range
Yes
DNS, lock in current range (Low), DNA
(0011 00-73)
33
C3 pressure switch open, 3rd range
Yes
DNS, lock in current range (3rd), DNA
55
C3 pressure switch open, 5th range
Yes
DNS, lock in current range (5th), DNA
77
C3 pressure switch open, Reverse
range
Yes
DNS, lock in current range (R), DNA
33
(0011 0-75)
12
Sump oil temperature sensor failed
low
No
Use default value of 93°C (200°F)
23
Sump oil temperature sensor failed
high
No
Use default value of 93°C (200°F)
Table 52. WT Series Diagnostic Codes (Continued)
Main
Code
Sub-
code
Description
CHECK
TRANS
Light
Inhibited Operation
Description