TM 9-2320-302-20
0010 00-17
Table 1. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Instrument Wiring Circuits - Continued
6. Axle Lock Indicator Light Does Not Operate -
Continued.
3. Disconnect lead 87 from axle
lock pressure switch. Check
for continuity between lead 87
and ground.
If no continuity is indicated, repair
lead 87 (WP 0119 00).
Ether Cold-Start Circuit
Ether Cold-start Does Not Operate When
Container Has Ether.
1. Check ether 10A fuse.
Replace 10A fuse if defective (WP
0071 00).
2. Remove
ether
15A
fuse.
Check for +12 VDC at fuse
connector from ignition run
power bus.
If +12 VDC is present, go to step
3. If voltage is not present, repair
circuit 18 (WP 0119 00).
3. Disconnect lead 166 from
ether switch. Check for +12
VDC at lead 166.
If +12 VDC is present, go to step
4. If voltage is not present, repair
lead 166 (WP 0119 00).
4. Disconnect lead 166A at cab/
chassis connection. Check for
+12 VDC at lead 166A.
If +12 VDC is present, go to step
5. If voltage is not present, repair
lead 166A (WP 0119 00).
5. Disconnect lead 166A from
ether solenoid. Check for +12
VDC at lead 166A.
If +12 VDC is present, go to step
6. If voltage is not present, repair
lead 166A (WP 0119 00).
6. Disconnect ground lead from
ether
solenoid.
Check
for
continuity
between
ground
lead and ground.
If continuity is indicated, replace
ether solenoid (WP 0035 00). If
continuity is not indicated, repair
ground lead (WP 0119 00).
Air Dryer Heater Circuit
Air Dryer Heater Does Not Operate.
1. Check reservoir heater/power
take-off 15A fuse.
Replace 15A fuse if defective (WP
0071 00).
2. Disconnect lead 94 from air
dryer
drain
valve
heater.
Check for +12 VDC at lead 94.
If +12 VDC is present, go to step
3. If voltage is not present, repair
lead 94 (WP 0119 00).
3. Disconnect ground lead from
air dryer drain valve heater.
Check for continuity between
lead and ground.
If continuity is indicated, replace
air dryer drain valve heater. If
continuity is not indicated, repair
ground lead (WP 0119 00).
Standard Heater Circuits
Heater Fan Does Not Operate at Any Speed.
1. Check heater fan 30A fuse.
Replace 30A fuse if defective (WP
0071 00).
2. Check
start/auxiliary
15A
fuse.
Replace 15A fuse if defective (WP
0071 00).
3. Remove heater fan 30A fuse.
Check for +12 VDC at lead 14
fuse connector.
If +12 VDC is present, go to step
4. If voltage is not present, repair
lead 14 to 12-volt constant power
bus (WP 0119 00).