TM 9-2320-302-20
0010 00-10
Table 1. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Auxiliary Light Circuits - Continued
1. Auxiliary Lights or Accessory Circuits Do Not
Operate - Continued.
5. Disconnect
auxiliary
lights
accessory
lockout
relay.
Check
for
+12
VDC
at
connector 85.
If +12 VDC is present, go to step
6. If voltage is not present, check
start/auxiliary
15A
fuse.
If
defective, replace 15A fuse (WP
0071 00). Check for continuity in
lead 71AA and lead 71A. If
continuity is not indicated, repair
lead 71AA and lead 71A (WP
0119 00). If voltage is still not
present at connector 85, replace
vehicular light switch (WP
0063 00).
6. Disconnect
auxiliary
lights
accessory
lockout
relay.
Check
for
continuity
in
connectors
30
and
86
to
ground.
If continuity is indicated, go to
step
7.
If
continuity
is
not
indicated, repair connector lead 30
or connector lead 86 to ground
(WP 0119 00).
7. Check
for
+12
VDC
at
auxiliary light power bus.
If +12 VDC is not present, check
for continuity in lead 420JD. If
continuity is indicated, replace
auxiliary lights power relay (WP
0071 00).
2. No Power to Auxiliary Heater Fan Power Relay. Disconnect
auxiliary
lights
accessory lockout relay and heater
fan
power
relay.
Check
for
continuity in lead 71AA.
If continuity is not indicated,
repair lead 71AA (WP 0119 00).
Worklight Power Receptacle Circuits
1. Worklight Power Receptacles Do Not Operate. 1. Check worklight receptacles
15A fuse.
Replace 15A fuse if defective (WP
0071 00).
2. Check for +12 VDC at lead
420JD from auxiliary light
power bus.
If +12 VDC is present, go to step
3. If voltage is not present, repair
lead 420JD (WP 0119 00).
3. Check for +12 VDC at lead
73F for left and right worklight
power receptacles.
If +12 VDC is present, repair
ground lead from worklight power
receptacles. If voltage is not
present, repair lead 73F (WP
0119 00).
2. One Worklight Power Receptacle Does Not
Operate, But Other Receptacle Operates
Normally.
1. Check for +12 VDC at lead
73F
to
worklight
power
receptacle.
If +12 VDC is present, go to step
2. If voltage is not present, repair
lead 73F (WP 0119 00).
2. Check for continuity between
receptacle and ground.
If continuity is indicated, replace
defective receptacle. If continuity
is not indicated, repair ground lead
(WP 0119 00).