TM 9-2320-302-20
0010 00-8
Table 1. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Turn Signal and Stoplight Circuits - Continued
3. Flasher Lights Do Not Operate.
1. Inspect light bulbs.
Replace
bulbs
if
broken
or
defective (WP 0088 00).
2. Disconnect left flasher relay
from connector. Check for +24
VDC at connector 30.
If +24 VDC is present, go to step
3. If voltage is not present, repair
lead 421 (WP 0119 00).
3. Check for continuity between
connector 86 and ground.
If continuity is indicated, go to
step
4.
If
continuity
is
not
indicated, repair ground lead (WP
0119 00).
4. Check
for
+12
VDC
at
connector 85.
If +12 VDC is present, go to step
5. If voltage is not present, repair
lead 60 (WP 0119 00).
5. Set turn signal switch in turn
mode. Install jumper leads
between connectors 30, 85,
and 86 to their respective
connectors at left flasher relay.
Check for +24 VDC at flasher
relay connection 87.
If +24 VDC is present, go to step
6. If voltage is not present, replace
left flasher relay (WP 0071 00).
6. Set turn signal switch in turn
mode. Check for +24 VDC at
trailer receptacle connectors.
If voltage is not present, repair
leads (WP 0119 00).
4. Turn Signal Lights Do Not Operate.
1. Inspect light bulb.
Replace
bulb
if
broken
or
defective (WP 0088 00).
2. Remove lamp from defective
left turn signal light. Check for
continuity
between
contact
points.
If continuity is indicated, go to
step
3.
If
continuity
is
not
indicated, replace lamp (WP
0088 00).
3. Remove signal light lamp.
Check for continuity between
socket and ground.
If continuity is indicated, repair
lead 60. If continuity is not
indicated, repair ground lead (WP
0119 00).
5. Turn Signal Indicator Light Does Not Operate,
But Turn Signals Operate Normally.
1. Inspect light bulb.
Replace
bulb
if
broken
or
defective (WP 0061 00).
2. Disconnect lead 60A from
warning light bar. Check for
+24 VDC at lead 60A.
If
+24
VDC
is
present,
troubleshoot warning light circuit.
If voltage is not present, repair
lead 60A (WP 0119 00).
Dome Light Circuits
1. Dome Lights Do Not Operate.
1. Check dome/auxiliary/flasher
lights 15A fuse.
Replace 15A fuse if defective (WP
0071 00).
2. Disconnect lead 420J from
dome/auxiliary/flasher
15A
fuse. Check for +12 VDC at
lead 420J.
If +12 VDC is present, repair lead
41 (WP 0119 00). If voltage is not
present, go to step 3.