TM 9-2320-302-20
0228 00-11
GENERAL MAINTENANCE INSTRUCTIONS - CONTINUED
0228 00
MULTIMETER - CONTINUED
CAUTION
Before performing a continuity test, always turn master battery switch to OFF position and disconnect cir-
cuit to be tested. Failure to follow this caution may damage multimeter.
c.
Testing for Shorts. A short (or short circuit) occurs when two circuits that should not be connected have metal-to-
metal contact with each other. A short also occurs when a circuit that should not touch ground has metal-to-metal
contact with ground.
(1)
Zero multimeter.
(2)
Connect black probe (4) to one circuit and red probe (5) to either a ground or another circuit.
(3)
Read digital readout (6) and interpret results as follows:
(a) If digital readout (6) indicates 0 (zero), circuits are shorted or circuit is grounded if testing to ground.
(b)
If digital readout (6) does not indicate 0 (zero), circuits are not shorted.
(c) If digital readout (6) jumps or flickers, circuits are shorted or grounded intermittently.
BLACK
RED
ORANGE
BLUE
TESTING FOR SHORTS
4
5
6