TM 9-2320-302-20
0119 00-13
ELECTRICAL CONNECTORS MAINTENANCE - CONTINUED
0119 00
COMMERCIAL CONNECTOR REPAIR - CONTINUED
b.
Installation. Use the following instructions for terminal installation:
(1)
Insert terminal into locating hole of crimping tool using proper hole according to gage of cable to be used
(Figure 7).
Figure 9. Terminal Position.
(2)
Insert cable into terminal until stripped position is positioned in cable core wings, and seal and insulated
portion of cable are in insulation wings (Figure 8).
Figure 10. Cable and Terminal Position Before and After Crimping.
J38706
OR EQUIVALENT
CABLE
SEAL
TERMINAL
INSULATION WINGS
CABLE CORE
WINGS
BEFORE
AFTER