TM 9-2320-302-20
0042 00-1
COOLANT HOSES, PIPES, AND CLAMPS REPLACEMENT
0042 00
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Tools and Special Tools
Tool kit, general mechanics (Item 36, WP 0236 00)
Pliers, slip joint (Item 50, WP 0236 00)
Materials/Parts
Nut, lock (P/N MS51922-1) (2)
Compound, sealing, pipe (Item 10, WP 0235 00)
References
TM 9-2320-302-10
Equipment Condition
Cooling system drained (WP 0041 00)
REMOVAL
1.
Loosen four clamps (1) and remove two hoses (2) and pipe (3) from thermostat housing (4) and radiator (5).
2.
Remove two lock nuts (6), four washers (7), two screws (8), and four clamps (9) from radiator support rod (10) and hose
(11). Discard lock nuts.
3.
Loosen two clamps (12) and remove hose (11) from radiator (5) and elbow (13).
3
1
2
1
12
13
4
11
1
2
1
5
9
7
6
10
8
79
11
12