CLEANING - Continued
WARNING
Improper cleaning methods and use of unauthorized cleaning solvents may injure
personnel and damage equipment. Failure to comply may result in death or injury
to personnel. Seek medical attention in the event of an injury.
Cloths or rags saturated with solvent cleaning compound must be disposed of
using IAW authorized facilities procedures. Failure to comply may result in death or
injury to personnel. Seek medical attention in the event of an injury.
Remove grease and oil with cleaning compound solvent and a clean rag.
END OF TASK
INSTALLATION
1.
Apply antiseizing tape to threads of dump valve (Figure 2, Item 3) and install valve onto air reservoir
(Figure 2, Item 1).
2.
Connect dump valve release cable (Figure 2, Item 2) to dump valve (Figure 2, Item 3).
1
3
2
2
466-0076a
Figure 2.
Dump Valve Installation.
END OF TASK