Table 1. Unit Preventive Maintenance Checks and Services (PMCS) - Continued.
CHAPTER 6. UNIT TROUBLESHOOTING

Repair Parts For Air Conditioner And Stowage Box Kit Model 7336 And Het Model 1070, 8X8 Page Navigation
  82    83    84    85    86  87  88    89    90    91    92  
img
. . .
TB 9-2320-360-13&P-1
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0013 00
Table 1. Unit Preventive Maintenance Checks and Services (PMCS) - Continued.
Location
Item
Item to Check/
Not Fully Mission
No.
Interval
Service
Procedure
Capable if:
N OT E
Perform the following during routine doghouse maintenance.
a. Remove evaporator subsystem (WP 0036
2
Semi-annual
A/C System (Dog-
00).
house Components)
b.Clean evaporator coil (1); check for dam-
age.
c. Check A/C system hoses (2) for cracks and
damage.
HETF00228
d.Perform A/C system leak test (WP 0038
00).
e. Install evaporator subsystem (WP 0036 00).
END OF WORK PACKAGE