OPERATOR'S TROUBLESHOOTING PROCEDURES
Table 1. Operator's Troubleshooting - Continued.

Repair Parts For Air Conditioner And Stowage Box Kit Model 7336 And Het Model 1070, 8X8 Page Navigation
  74    75    76    77    78  79  80    81    82    83    84  
img
. . . .
TB 9-2320-360-13&P-1
OPERATOR'S TROUBLESHOOTING - A/C BLOWER OPERATES
BUT NO COLD AIR FROM A/C DUCTS
0011 00
Table 1. Operator's Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
A/C BLOWER OPERATES BUT NO COLD AIR FROM A/C DUCTS.
Step 1.
Check A/C intake filter for dust and debris that may restrict air flow.
Clear dust and debris from A/C intake filter (WP 0007 00).
Step 2.
Check if A/C control switch is set to the correct operating position (WP 0008 00).
Place A/C control switch to correct operating position.
Step 3.
Ensure personnel heater is off and all cab windows and recirculating/fresh air vents are closed.
Turn personnel heater off and close all cab windows and recirculating/fresh air vents
(TM 9-2320-360-10).
Step 4.
Check if A/C engine fan control solenoid circuit breaker has been tripped.
Reset tripped A/C engine fan control solenoid circuit breaker.
HETF00226
0011 00-1