TB 9-2320-302-13&P-3
A/C TROUBLESHOOTING PROCEDURES - CONTINUED
0013 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
A/C ELECTRICAL SYSTEM - CONTINUED
1. If continuity is not indicated,
2.
A/C System Energized But
wire terminal on A/C fan switch
repair or replace blue wire.
and blue wire terminal on speed
Function - Continued.
2. If continuity is indicated, replace
resistor connector.
speed resistor.
(c) Return equipment to normal
condition.
7. Verify A/C fan switch high speed setting.
(a) Turn ignition key switch to the OFF
position (TM 9-2320-363-10).
(b) Set A/C fan switch to the OFF
(c) Remove A/C fan switch connector
from A/C fan switch inside
1. If continuity is not indicated,
"B" and contact "H" on A/C fan
switch.
2. If continuity is indicated, proceed
to next step.
(f) Return equipment to normal
condition.
8. Verify blower high speed circuit to speed
resistor.
(a) Remove A/C fan switch connector
from A/C fan switch inside
1. If continuity is not indicated,
wire terminal on A/C fan switch
repair or replace orange wire.
and orange wire terminal on speed
2. If continuity is indicated, replace
resistor connector.
speed resistor.
(c) Return equipment to normal
condition.
9. Verify ground to blower motor.
(a) Turn ignition key switch to the OFF
position (TM 9-2320-363-10).
0013 00-9