TB 9-2320-302-13&P-3
A/C TROUBLESHOOTING PROCEDURES - CONTINUED
0013 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
A/C ELECTRICAL SYSTEM - CONTINUED
(c) Attempt to spin fan motor.
1. If motor is seized, replace fan
2.
A/C System Energized But
Function - Continued.
2. If motor is not seized, proceed to
next step.
(d) Return equipment to normal
condition.
2. Verify operation of A/C fan switch.
(a) Turn ignition key switch to the ON
position (TM 9-2320-363-10).
(b) Set A/C fan switch to the ON
(c) Cycle A/C fan switch through
1. Observe blower operation. If
blower does not operate on any
speed, go to step 9.
2. If blower does not operate on one
speed setting, troubleshoot non-
functional circuit (LOW speed
step 3, MEDIUM speed step 5,
HIGH speed step 7).
3. If blower does not operate on two
speed settings, replace resistor
(d) Return equipment to normal
condition.
3. Verify A/C fan switch low speed setting.
(a) Turn ignition key switch to the OFF
position (TM 9-2320-363-10).
(b) Set A/C fan switch to the OFF
(c) Remove A/C fan switch connector
from A/C fan switch inside
1. If continuity is not indicated,
"B" and contact "L" on A/C fan
switch.
to next step.
0013 00-7