Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued.
Location
Item To
Item
Check/
Not Fully Mission
No.
Interval
Service
Procedure
Capable If:
9
Before
Side Armor
e. Inspect wheel well blast deflector for Any wheel well blast deflector is dam-
(Con't)
(Right Side)
damage, loose, or missing mounting aged or mounting hardware is loose or
missing.
hardware.
f. Inspect wheel well blast deflector Any corrosion where area is unsound
and small pin holes are present, or a
frame for areas of rust or corrosion.
rusted through condition is present.
g.Inspect right firewall armor panel for Any armor panel assembly is damaged
damage, loose, or missing mounting or mounting hardware is loose or miss-
ing.
hardware.
h.Inspect right firewall armor frames for Any corrosion where area is unsound
and small pin holes are present, or a
areas of rust or corrosion.
rusted through condition is present.
DOOR BALLISTIC GLASS
A-PILLAR
ARMOR
RIGHT FIREWALL
ARMOR (HIDDEN)
B-PILLAR
WHEEL WELL
ARMOR
440-009
BLAST DEFLECTORS
DOOR ARMOR
0009 00-12