TB 9-2320-302-13&P-2
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0009 00
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued.
Location
Item To
Item
Check/
Not Fully Mission
No.
Interval
Service
Procedure
Capable If:
8
Before
Underbody
Inspect right and center underbody mine Any mine blast panel is damaged or
Mine Blast
blast panels under cab for damage, mounting hardware is loose or missing.
Panel (Right
loose, or missing mounting hardware.
Side)
RIGHT UNDERBODY
MINE BLAST PANEL
440-084
UNDERBODY
CENTER UNDERBODY
MINE BLAST PANELS
MINE BLAST PANEL
9
Before
Side Armor
a. Inspect A-pillar and B-pillar armor Any side A-pillar or B-pillar armor or
(Right Side)
panels and door assembly for damage, door assembly is damaged or mounting
loose, or missing mounting hardware. hardware is loose or missing.
b.Inspect A-pillar and B-pillar frames Any corrosion where area is unsound
and door assembly frames for areas of and small pin holes are present, or a
rusted through condition is present.
rust or corrosion.
c. Inspect door ballistic glass mounting Any ballistic glass mounting hardware
hardware for damage, loose, or miss- is damaged, loose, missing, or mounting
bolts are loose or missing.
ing mounting hardware.
d.Inspect exterior surface of door ballis-
Rock chips, cracks with spider webbing,
tic glass for rock chips, cracks,
scratches, pitting, or damage in the exte-
scratches, pitting, any damage that
rior layer of ballistic glass that expose
expose glass below the first layer,
glass below the first layer, or cloudiness
cloudiness, or any stickers that impair
that impairs vision.
vision.
0009 00-11